Installing Your SoClean Adapter

Congratulations on purchasing a SoClean! Using the SoClean will help keep your CPAP machine clean and ready to use. If you haven't already picked out an adapter, please check out our compatibility chart here. If you have your adapter and are ready to install it, please select it below.

Please pick your SoClean adapter by clicking on the image below:

 

How to Install the SoClean CPAP Adapter for ResMed AirSense 10

This CPAP adapter is necessary to ensure that the Resmed Airsense™ 10 CPAP machine continues to function properly while the user’s system is connected to the SoClean CPAP Cleaner and Sanitiser. This CPAP adapter works with all SoClean models and will ensure effective cleaning of your CPAP machine.

To install the adapter, please follow the steps listed below:

1. Detach the injection fitting and short hose from the main SoClean hose. You will no longer need the injection fitting and short hose. Save these parts in case you need them in the future

2. Remove the original lid from the reservoir base by opening the lid fully, pushing one side of the hinge tab outward and freeing the lid from the base.

3. Lift the gasket from the original lid and transfer it to the new lid.

4. Install the new lid with the black injection hose to the reservoir base by inserting the left pin into the left notch. Pull the lid toward you and insert the right pin into the right notch.

5. If needed, refill your reservoir. Close the new lid and insert the reservoir into your CPAP unit like you normally would.

6. Connect the SoClean tube by pushing it onto the end of the port of the adapter lid.

When you need to add water to your reservoir please remove the SoClean tube from the adapter lid and remove the reservoir from the CPAP machine. Add water and reinsert into the CPAP machine and then reconnect the SoClean hose. WARNING: hose must be attached to lid at all times when using.

How to Install the SoClean CPAP Adapter for ResMed S9

This CPAP adapter is necessary to ensure that the ResMed S9 AutoSet™ CPAP machine continues to function properly while the user’s system is connected to the SoClean CPAP Cleaner and Sanitiser. This CPAP adapter works with all SoClean models and will ensure effective cleaning of your CPAP machine.

To install the CPAP adapter, please follow the steps listed below:

1. Detach the injection fitting and short hose from the main SoClean hose. You will no longer need the injection fitting and short hose. Save these parts in case you need them in the future.

2. Remove the original lid from your humidifier by opening the lid fully, grasping it near the hinges and pushing firmly away from the unit.

3. Remove the silicone gasket from the original lid and install it onto the new lid, making sure the gasket lies flat and fits over the two tabs. Install the new lid with the black injection hose by lining up the hinges and pulling firmly toward you until you hear a clicking in both hinges.

4. Add water to your reservoir, if needed. When closing the new lid, make sure that the hose on the underside passes into the reservoir opening and rests near the bottom.

5. Attach the reservoir lid stem to the main tube connected to the check valve assembly.

To achieve the proper seal, firmly push down on the lid top until you hear a click.

How to Install the SoClean CPAP Adapter for Philips Respironics DreamStation and System One

This CPAP adapter is necessary to ensure that the Philips Respironics DreamStation CPAP machine continues to function properly while the user’s system is connected to the SoClean CPAP Cleaner and Sanitiser. This CPAP adapter works with all SoClean models and will ensure effective cleaning of your CPAP machine.

How to setup the SoClean with the DreamStation:

1. Detach the injection fitting and short hose from the main SoClean hose. You will no longer use the injection fitting and short hose. Save these parts in case you need them in the future.

2. Connect the main hose from the SoClean to the stem on the side of the adapter.

3. Open the reservoir lid.

4. Feed the injection hose down into your reservoir through the port. Attach the adapter to your reservoir. Do not detach the injection hose from the adapter at any point.

5. Close the reservoir lid and attach the CPAP hose to the adapter.

If your System One CPAP has a heated hose connection, please follow these steps:

1. Detach the injection fitting and short hose from the main SoClean hose. You will no longer use the injection fitting and short hose. Save these parts in case you need them in the future.

2. Connect the main hose from the SoClean to the stem on the side of the adapter.

3. Open the reservoir lid.

4. Feed the injection hose down into your reservoir through the port. Attach the adapter to your reservoir. Note: Do not detach the injection hose from the adapter at any point.

5. Close the reservoir lid and attach the CPAP hose to the adapter.

How to connect the diffuser to the System One CPAP with a standard hose connection:

For this setup, you will not need the CPAP adapter. You will only need the diffuser. This is the short length of hose with a clear plastic fitting on the end.

1. Detach the short hose from the inner stem of the injection fitting.

2. Attach the diffuser to the stem on the inside of the injection fitting. You may use a little water as a lubricant to make it easier.

3. Open the reservoir lid.

4. Feed the diffuser down into your reservoir through the port, until the clear plastic end rests at the bottom of the reservoir. Attach the injection fitting to your reservoir.

5. Close the reservoir lid and attach the CPAP hose to the injection fitting.

How to Install the SoClean CPAP Adapter for Fisher & Paykel Icon

This CPAP adapter is necessary to ensure that the Fisher & Paykel ICON™ CPAP machines continues to function properly while the user’s system is connected to the SoClean CPAP Cleaner and Sanitiser. This CPAP adapter works with all SoClean models and will ensure effective cleaning of your CPAP machine.

The CPAP adapter for the Fisher & Paykel Icon is a special fitting. The adapter replaces the original elbow fitting on your machine.

To install the CPAP adapter, please follow the steps listed below:

1. Detach the injection fitting and short hose from the main SoClean hose.

2. Disconnect the short hose from the inside of the injection fitting.

3. Install the short hose to the stem on the inside of the new Icon adapter.

4. Connect the main hose from the SoClean to the stem on the outside of the Icon adapter.

5. Detach your CPAP hose from the elbow fitting on the back of your Icon CPAP.

6. Detach the original elbow fitting from the back of the Icon CPAP.

7. Grasping the Icon adapter, guide the short black hose into the humidifier reservoir using a pushing and twisting motion. Note: It may be necessary to trim off some of the hose. The end should rest near but not touch the bottom of the reservoir. Snap the adapter into place.

Connect your CPAP hose to the new Icon adapter.

How to Install the SoClean CPAP Adapter for Fisher & Paykel 600 Series

This CPAP adapter is necessary to ensure that the Fisher & Paykel SleepStyle 600 Series CPAP machine continues to function properly while the user’s system is connected to the SoClean CPAP Cleaner and Sanitiser. This CPAP adapter works with all SoClean models and will ensure effective cleaning of your CPAP machine.

To install the CPAP adapter, please follow the steps listed below:

1. Remove the original humidifier reservoir from your CPAP unit.

2. Insert the new reservoir adapter with black hose in the same way you normally install your reservoir.

3. Detach the injection fitting and short hose from the main SoClean hose. You will no longer need the injection fitting and short hose. Save these parts in case you need them in the future.

4. Connect the main hose from the SoClean to the short reservoir hose by pushing the main hose onto the Easy Disconnect. The Easy Disconnect coupling makes it simple to disconnect the hose when you need to remove your reservoir for filling and maintenance.

How to Install the SoClean CPAP Adapter for Transcend & Z1 CPAP Machines

The SoClean adapter for the Transcend & Z1 is a special fitting designed to connect a Transcend CPAP model or a Z1 CPAP model to the SoClean. This CPAP adapter works with all SoClean models and will ensure effective cleaning of your CPAP machine.

To install the CPAP adapter, please follow the steps listed below:

1. Remove the hose from your Transcend or Z1 device.

2. Install the Transcend and Z1 SoClean adapter onto the CPAP hose.

3. Detach the injection fitting and short hose from the main SoClean hose. You will no longer need the injection fitting and short hose. Save these parts in case you need them in the future.

4. Connect the SoClean injection hose to the Transcend and Z1 SoClean adapter.

5. Once the sanitising cycle is complete and you are ready to use your Transcend or Z1 CPAP please remove the Transcend and Z1 SoClean adapter from your CPAP hose and reconnect your CPAP hose to the CPAP device.

How to Install the SoClean CPAP Adapter for AirMini & DreamStation Go

The SoClean adapter for the ResMed Airmini and Respironics DreamStation Go is a special fitting designed to connect an AirMini CPAP model or a DreamStation Go CPAP model to the SoClean. This CPAP adapter works with all SoClean models and will ensure effective cleaning of your CPAP machine.

To install the CPAP adapter for the ResMed AirMini, please follow the steps listed below:

1. Disconnect your CPAP hose from your ResMed AirMini.

2. Detach the injection fitting and short hose from the main SoClean hose. You will no longer need the injection fitting and short hose. Save these parts in case you need them in the future.

3. Included in the adapter package are three small, rubber gaskets. Place one gasket inside the adapter. Save the remaining gaskets in case the original needs to be replaced.

4. Attach the SoClean adapter to your CPAP hose.

5. Connect the main SoClean hose to the stem on the adapter.

6. You are now ready to use your SoClean.

7. Once the sanitising cycle is complete and you are ready to use your CPAP machine, please remove the adapter from your CPAP hose and reconnect the CPAP hose to your AirMini CPAP machine.

To install the CPAP adapter for the Respironics DreamStation Go, please follow the steps listed below:

1. Disconnect your CPAP hose from your Philips Respironics DreamStation Go.

2. Detach the injection fitting and short hose from the main SoClean hose. You will no longer need the injection fitting and short hose. Save these parts in case you need them in the future.

3. Included in the adapter package are three small, rubber gaskets. Please disregard the gaskets. You will not need them for the DreamStation Go CPAP machine.

4. Attach the SoClean adapter to your CPAP hose.

5. Connect the main SoClean hose to the stem on the adapter.

6. You are now ready to use your SoClean.